Quick answer: use the grade, capacity and interval in your own model’s manual; the 26 portable-generator manuals we read don’t agree with each other, and a few don’t agree with themselves.
- 18 of the 26 manuals recommend 10W-30 for general use. The other 8 (Generac ×5, WEN ×3) choose by temperature: SAE 30 or 30W in warm weather, 10W-30 only in a cold band, and synthetic 5W-30 for every temperature (the older Generac GP 3250: only below 10 °F).
- 14 of the 26 hold 0.55–0.6 L (roughly 19–20 fl oz). The range across all 26 is 0.35 L to 1.2 L.
- A 1-quart (32 fl oz) bottle is more than the printed capacity of 23 of the 26. The three that hold more: A-iPower AP10000ED (33.8 fl oz), Predator 57480 (1.1 qt) and DuroMax XP13000EH (40.5 fl oz).
- None of the 26 portables has an oil filter on the unit.
- First change after 5 to about 30 hours. Then every 100 hours on 18 manuals, every 50 hours on 5, every 25 hours on the WEN 56203i, and about every 20 hours or monthly on the DuroMax XP5500X and (the schedule is ambiguous) the Predator 57480.
- The dipstick trap: 15 manuals say don’t screw the dipstick in to read the level, 4 say screw it in.
We read the owner’s manuals for 26 portable generator models from nine brands and copied each oil grade, capacity and change interval as printed, with its page. Sources were fetched 18 October 2026. It is the oil companion to our generator spark plug guide, built the same way: no source, no number.
Coverage: the Honda EU2200i and EU2200i Companion share one manual (a later edition, 00X31-Z44-6020, has identical oil text on the same pages), the Generac GP5500E is read from the GP Series manual, the Honda EU3000is is the 2009 printing and the Generac GP 3250 is an older manual. Match your own manual’s edition and part number; a different printing can differ. We could not obtain Briggs & Stratton, Ryobi or Pulsar generator manuals, so those brands are not covered. The standby section covers Generac’s air-cooled home standby units from three of its manuals. For engines outside this list, the Small Engine Oil Finder looks oil up by engine, which these manuals don’t do.
Oil type, capacity and change interval by model
Copied as printed, with the printed unit. Page numbers are the ones printed on the manual’s pages. The converted figure under each capacity is our arithmetic from the printed figure (1 fl oz = 29.5735 mL). † marks a manual whose own US and metric figures disagree once converted; ‡ marks an ambiguous schedule. Both are explained under the table.
Scroll the table sideways →
| Model and source | Oil grade as printed | Capacity as printed | First change | Regular interval |
|---|---|---|---|---|
| Honda EU2200i / EU2200i Companion manual, pp. 46, 50, 51 | SAE 10W-30 for general use; API SJ or later (or equivalent) | Maximum oil capacity: 14 oz (0.44 L) = 14.9 fl oz / 0.44 L † | First month or 20 hrs | Every 6 months or 100 hrs |
| Honda EB2200i manual, pp. 37, 41, 42 | SAE 10W-30 for general use; API SJ or later (or equivalent) | Maximum oil capacity: 14 oz (0.44 L) = 14.9 fl oz / 0.44 L † | First month or 20 hrs | Every 6 months or 100 hrs |
| Honda EU3200i manual, pp. 14, 54, 55 | SAE 10W-30 for general use; API SJ or later (or equivalent) | Maximum oil capacity: 15 oz (0.46 L) = 15.6 fl oz / 0.46 L † | First month or 20 hrs | Every 6 months or 100 hrs |
| Honda EU3000is (2009 printing) manual, pp. 41, 45, 46, 75 | SAE 10W-30 for general use; API SJ or later (or equivalent) | Oil capacity 0.58 US qt (0.55 L) (spec table; the oil-change step prints no amount) = 18.6 fl oz / 0.55 L | First month or 20 hrs | Every 6 months or 100 hrs |
| Champion 100263 manual, pp. 10, 19, 20, 23 | 10W-30 automotive oil recommended; chart also shows 5W-30, 10W-40 and full synthetic 5W-30 | Add up to 0.6 L (0.6 qt.); one page prints 0.6 qt. (0.6 L) = 20.3 fl oz / 0.60 L † | First 5 hours (break-in) | Every 100 hours or every season |
| Champion 100264 manual, pp. 10, 19, 20, 23 | 10W-30 automotive oil recommended; chart also shows 5W-30, 10W-40 and full synthetic 5W-30 | Add up to 0.6 L (0.6 qt.); one page prints 0.6 qt. (0.6 L) = 20.3 fl oz / 0.60 L † | First 5 hours (break-in) | Every 100 hours or every season |
| Champion 100574-1 manual, pp. 14, 15, 25, 28 | 10W-30 automotive oil for typical use; chart for extreme temperatures (5W-30, 10W-40, 5W-30 synthetic) | Add up to 20.3 fl. oz. (600 ml) = 20.3 fl oz / 0.60 L | First 5 hours (break-in) | Every 100 hours or annually |
| Predator 59137 manual, pp. 2, 12, 15, 18 | SAE 10W-30 (“recommended for general use”) | Engine Oil Capacity 20 fl. oz. = 20.0 fl oz / 0.59 L | After break-in of about 30 hours | Every 6 mo. or 100 hr. of use |
| Predator 59135 manual, pp. 2, 11, 14, 18 | SAE 10W-30 (“recommended for general use”) | Engine Oil Capacity 13 fl. oz. = 13.0 fl oz / 0.38 L | After break-in of about 30 hours | Every 6 mo. or 100 hr. of use |
| Predator 57480 manual, pp. 7, 13, 14, 19, 20 | Spec table: 10W-30 above 32 °F, 5W-30 at 32 °F or below. Text: SAE 10W-30 for general use | Engine Oil Capacity 1.1 Quart = 35.2 fl oz / 1.04 L | After break-in of about 25 hours | ‡ Ticked from the “Monthly or every 20 hr. of use” column onward |
| Westinghouse iGen4500 manual, pp. 3, 10, 19, 20, 21 | 10W-30 (bottle supplied); chart for extreme temperatures | Oil Capacity: 0.63 US qt (0.60 L) = 20.3 fl oz / 0.60 L | After first 25 hours or first month | After 50 hours or every 6 months |
| Westinghouse iGen4500DF manual, pp. 3, 11, 21, 22, 23 | 10W-30 (bottle supplied); chart for extreme temperatures | Oil Capacity: 0.63 US qt (0.60 L) = 20.3 fl oz / 0.60 L | After first 25 hours or first month | After 50 hours or every 6 months |
| Generac iQ3500 manual, pp. 5, 8, 13 | By temperature (chart): SAE 30, 10W-30 or synthetic 5W-30 | Oil Capacity 0.6 L (0.6 qt.) = 20.3 fl oz / 0.60 L † | After first month or 20 hours | Every 100 hours or every 6 months |
| Generac GP3300i manual, pp. 5, 7, 12 | By temperature (chart): SAE 30, 10W-30 or synthetic 5W-30 | Oil Capacity 0.6 L (0.6 qt.) = 20.3 fl oz / 0.60 L † | After first month or 20 hours | Every 100 hours or every 6 months |
| Generac GP2500i manual, pp. 5, 13 | By temperature (chart): SAE 30, 10W-30 or synthetic 5W-30 | Oil Capacity 0.35 L (0.36 qt.) = 11.8 fl oz / 0.35 L | After first 30 hours (footnote) | Every 100 hours (footnote) |
| Generac GP5500E (GP Series manual) manual, pp. 7, 10, 17 | By temperature (chart): SAE 30, 10W-30 or synthetic 5W-30; supplied oil is SAE 30 | Oil Capacity 0.7 L (0.74 qt.) = 23.7 fl oz / 0.70 L | After first 30 hours | Every 100 hours or every year |
| Generac GP 3250 (older manual) manual, pp. 8, 9, 10 | API SJ, SL or better. Above 40 °F SAE 30; 40 to 10 °F 10W-30; below 10 °F synthetic 5W-30 | Oil Capacity 0.6 L (0.634 Qts.) = 20.3 fl oz / 0.60 L | After first 20 hours | Every 50 hours |
| WEN 56203i manual, pp. 3, 12, 23 | API SJ, SL or SM detergent oil; synthetic may be used. 30W above 40 °F, 10W-30 0–40 °F, synthetic 5W-30 all temperature ranges | Oil Capacity 17.1 fl. oz. (0.5 L); p. 12 prints 17.0 fl. oz. = 17.1 fl oz / 0.50 L | No separate first change printed | Every 25 hours (and as necessary) |
| WEN 56360i manual, pp. 3, 12, 17, 23 | API SJ, SL or SM detergent oil; synthetic may be used. 30W above 40 °F, 10W-30 0–40 °F, synthetic 5W-30 all temperature ranges | Oil Capacity 16.9 fl. oz. (0.5 L) = 16.9 fl oz / 0.50 L | After the first 8 hours, then again after the first 25 hours | Every 50 hours after that |
| WEN 56480iX manual, pp. 3, 18, 25, 26 | API SJ, SL or SM detergent oil; synthetic may be used. 30W above 40 °F, 10W-30 0–40 °F, synthetic 5W-30 all temperature ranges | Oil Capacity 20.3 fl. oz. (0.60 L) = 20.3 fl oz / 0.60 L | After the first 8 hours, then again after the first 25 hours | Every 50 hours after that |
| Firman W01682 manual, pp. 9, 10, 18 | 10W-30 automotive oil recommended; chart by outdoor temperature | Lubricating Oil Capacity 12.9 oz (0.38 L) = 12.8 fl oz / 0.38 L | After 25 hours (new engine) | Every 100 hours (or annual) |
| Firman P03617 manual, pp. 14, 15, 26 | 10W-30 automotive oil recommended; chart by outdoor temperature | Lubricating Oil Capacity 20.3 oz (0.6 L) = 20.3 fl oz / 0.60 L | After 25 hours (new engine) | Every 100 hours (or annual) |
| DuroMax XP13000EH manual, pp. 27, 58, 59 | SAE 10W-30 recommended; synthetic after the 8-hour break-in; full synthetic 5W-30 aids cold starts below 41 °F (5 °C) | Engine Oil Capacity 40.5 fl. oz (1.2 L) = 40.5 fl oz / 1.20 L | 1st mo. or 8 hrs (break-in) | Every 6 mo. or 100 hrs. of normal use |
| DuroMax XP5500X manual, pp. 23, 44 | SAE 10W-30 recommended | Engine Oil Capacity 20 fl. oz (0.6 L) = 20.0 fl oz / 0.60 L | No separate first change printed | Every mo. or 20 hrs |
| A-iPower SUA5001 manual, pp. 11, 12, 17 | SAE 10W-30 API SJ recommended; API SJ or higher detergent oils acceptable; use the chart for the outdoor temperature | Oil Capacity 18.6 fl. oz (0.55 L) = 18.6 fl oz / 0.55 L | First 5 hours (break-in), then first 25 hours or first month | Every 100 hours or 6 months |
| A-iPower AP10000ED manual, pp. 13, 16, 26 | SAE 10W-30 API SJ recommended; use the chart for the outdoor temperature | Oil Capacity 33.8 fl. oz (1.0 L) = 33.8 fl oz / 1.00 L | First 5 hours (break-in), then first 25 hours or first month | Every 100 hours or 6 months |
† Printed figures that don’t match. Honda EU2200i, EB2200i and EU3200i, Champion 100263 and 100264, and Generac iQ3500 and GP3300i print a US and a metric capacity that disagree by 4–6% once converted. The table and Figure 1 use the metric figure for those; the Honda EU2200i and EB2200i print 14 oz (0.44 L), but 14 US fl oz is 0.41 L and 0.44 L is 14.9 fl oz. ‡ Predator 57480. Ticked in the “Monthly or every 20 hr. of use” column and again at 6 months/100 hr, yearly and 2 years, but not at 3 months/50 hr (read from the schedule on p. 19). We can’t tell whether that means monthly, every 20 hours, or a longer interval.
Capacity at a glance
14 of the 26 manuals print about 0.55–0.6 L, which is why one bottle usually covers a change. The small end is the Generac GP2500i (0.35 L), then the Firman W01682 (0.38 L) and the Honda EU2200i and EB2200i (0.44 L). The large end is the DuroMax XP13000EH (1.2 L). Capacity is a maximum or an “up to”: fill to your manual’s level mark rather than pouring a measured amount (see the check-and-fill section).
Which oil for the temperature
18 manuals name 10W-30 for general use. The other 8 don’t: the five Generac manuals and the three WEN manuals tell you to choose by temperature, with SAE 30 (or 30W) in warm weather, 10W-30 in a cold band and synthetic 5W-30 for every temperature (the older Generac GP 3250: only below 10 °F). Figure 2 draws the 15 manuals, in six groups, that print numeric boundaries or a chart we could read.
- Champion is not charted. The charts come in two templates. The Champion 100263 uses the “Degrees Celsius (Outside)” template shared with Firman W01682 and P03617 and the DuroMax XP13000EH; the 100264 and 100574-1 use the “Recommended Engine Oil Type” template shared with Westinghouse and A-iPower. The bar ends read differently from one to the next: the 5W-30 band reaches about 30 °F on the 100263 and about 50–60 °F on the 100264, and on the 100574-1 it ends near 7 °F and its 10W-40 band starts near 80 °F. We read them by eye, so we don’t print boundaries. Use the chart in your own manual.
- Synthetic only after break-in. The four Generac portables that say so (iQ3500, GP3300i, GP2500i, GP5500E) supply petroleum oil for break-in and say to use it before synthetic. Champion 100263 and 100264 say synthetic may be used after the 5-hour initial break-in; the DuroMax XP13000EH says after its 8-hour break-in. WEN says “synthetic oils may be used”.
- Honda and Predator never mention synthetic. Across the seven Honda and Predator manuals we read, no printed grade or chart names it, so we can’t say what they allow.
- 10W-40 for heat. 10 manuals (Champion ×3, Firman ×2, Westinghouse ×2, A-iPower ×2, DuroMax XP13000EH) draw a 10W-40 band at the warm end, from about 70–80 °F up.
- Predator 57480 gives three answers. The spec table says 10W-30 above 32 °F and 5W-30 at 32 °F or below, the text says 10W-30 is recommended for general use, and the chart draws 10W-30 down to about -5 °F with 5W-30 overlapping it up to about 27–30 °F.
- Cold start. The Champion 100574-1 and DuroMax XP13000EH say full synthetic 5W-30 aids starting below 41 °F (5 °C).
When to change it
Only intervals the manuals print, in the manual’s own words. Most print both hours and a calendar limit.
Scroll the table sideways →
| Manual | First change | Regular interval | Under heavy load or heat |
|---|---|---|---|
| Honda EU2200i, Honda EB2200i, Honda EU3200i, Honda EU3000is | First month or 20 hrs | Every 6 months or 100 hrs | Not printed |
| Champion 100263, Champion 100264 | First 5 hours (break-in) | Every 100 hours or every season | Every 50 hours or every season |
| Champion 100574-1 | First 5 hours (break-in) | Every 100 hours or annually | Every 50 hours or annually |
| Predator 59137, Predator 59135 | After break-in of about 30 hours | Every 6 mo. or 100 hr. of use | Not printed |
| Predator 57480 | After break-in of about 25 hours | ‡ Ticked from the “Monthly or every 20 hr. of use” column onward | Not printed |
| Westinghouse iGen4500, Westinghouse iGen4500DF | After first 25 hours or first month | After 50 hours or every 6 months | Every month under heavy load or in high temperatures |
| Generac iQ3500 | After first month or 20 hours | Every 100 hours or every 6 months | Every month under heavy load or in high temperatures |
| Generac GP3300i | After first month or 20 hours | Every 100 hours or every 6 months | Monthly under heavy load or high temperatures |
| Generac GP2500i | After first 30 hours (footnote) | Every 100 hours (footnote) | Monthly under heavy load or high temperatures |
| Generac GP5500E | After first 30 hours | Every 100 hours or every year | Monthly under heavy load or high temperatures (footnote says oil and oil filter) |
| Generac GP 3250 | After first 20 hours | Every 50 hours | Every month under heavy load or in high temperatures |
| WEN 56203i | No separate first change printed | Every 25 hours (and as necessary) | More often in dust, under heavy load or in high ambient temperatures (no number printed) |
| WEN 56360i, WEN 56480iX | After the first 8 hours, then again after the first 25 hours | Every 50 hours after that | More often under heavy load or high ambient temperatures (no number printed) |
| Firman W01682 | After 25 hours (new engine) | Every 100 hours (or annual) | More often in extremely dirty or dusty conditions or extremely hot weather (no number printed) |
| Firman P03617 | After 25 hours (new engine) | Every 100 hours (or annual) | More often in extremely dirty or dusty or hot conditions (no number printed) |
| DuroMax XP13000EH | 1st mo. or 8 hrs (break-in) | Every 6 mo. or 100 hrs. of normal use | Every 3 mo. or 50 hrs. of heavy use |
| DuroMax XP5500X | No separate first change printed | Every mo. or 20 hrs | More frequent service under sustained high load or high temperature (no number printed) |
| A-iPower SUA5001 | First 5 hours (break-in), then first 25 hours or first month | Every 100 hours or 6 months | Every month under heavy load or in high temperatures |
| A-iPower AP10000ED | First 5 hours (break-in), then first 25 hours or first month | Every 100 hours or 6 months | Monthly under heavy load or high temperatures |
- First change: 5 to about 30 hours. Champion and A-iPower say 5 hours; the two WEN inverters say 8 and then 25; the Honda, Generac iQ3500 and GP3300i say the first month or 20 hours; Predator says about 25 to 30 hours of break-in. The WEN 56203i and DuroMax XP5500X print no separate first change.
- Regular interval. 18 manuals print 100 hours (most with a calendar alternative); 5 print 50 hours (the two Westinghouse, the Generac GP 3250 and the WEN 56360i and 56480iX); the WEN 56203i prints 25; and the DuroMax XP5500X prints “Every mo. or 20 hrs”. The Predator 57480 may mean the same (‡).
- Monthly under heavy load or heat. 9 manuals (both Westinghouse, four Generac portables, the Generac GP 3250 and both A-iPower) say to change oil every month under heavy load or in high temperatures. Champion halves it to 50 hours, the DuroMax XP13000EH says every 3 months or 50 hours of heavy use, and WEN and Firman say “more often” with no number.
A generator that runs for days after a storm reaches these hour counts quickly. This is arithmetic, not a rule from the manuals: running nonstop, the printed hours work out to
| Hours printed | Days of nonstop running |
|---|---|
| 20 hours | about 0.8 days |
| 25 hours | about 1.0 days |
| 50 hours | about 2.1 days |
| 100 hours | about 4.2 days |
so a generator carrying the house through a long outage can be due for its first change, or a regular one, within the week. Check your row and keep the right oil on hand before the storm.
How to check and fill the oil
Level ground, engine off and cool, then read the level with the dipstick the way your manual says. The manuals don’t agree on how.
- 15 manuals say don’t screw the dipstick in: Honda ×4, Champion ×3, Westinghouse iGen4500, Generac iQ3500, GP3300i and GP2500i, Predator 57480 and WEN ×3. You rest the dipstick in the neck and read it.
- 4 say screw it in: Westinghouse iGen4500DF, Generac GP5500E and both A-iPower manuals.
- 4 say fill to the edge or lip of the hole: Predator 59137 and 59135 (“up to the edge of the hole”) and both DuroMax manuals (the lower lip of the fill opening; the DuroMax manuals say to insert the dipstick “as if you were replacing the cap”). They don’t say plainly whether to screw it in for the reading.
- 3 don’t say: the older Generac GP 3250 (fill to the high mark on the dipstick) and both Firman manuals (pour to the H mark; fully tighten the cap).
What to fill to. It differs by model, so find yours: the upper limit of the oil filler neck (Honda), the upper limit mark or halfway up the fill threads (WEN), the H mark (Firman, A-iPower and Westinghouse’s L–H range), the high mark (Generac GP 3250), the full mark (Predator 57480), the edge of the hole (other Predator) or the lower lip (DuroMax). Champion prints “about 1-2 threads from running out of the fill hole”. Capacity is a maximum, so fill to the level rather than a measured amount, and add slowly. Westinghouse says to pour slowly and stop frequently.
- All 26 manuals describe a low-oil shutdown or sensor (Honda calls it Oil Alert). The manuals still tell you to check the level: Champion 100263 says daily or every 8 hours, and Firman W01682 says before each use or every 8 hours.
- A funnel: 15 of the 26 tell you to fill through one, and 17 ship one in the box (Champion, Westinghouse, Generac iQ3500, GP3300i and GP2500i, WEN, Firman, DuroMax and A-iPower). Honda, Predator, the Generac GP5500E and GP 3250 don’t.
- Some ship with oil in the box (Westinghouse, Generac, Firman, A-iPower). The Honda EU2200i manual says the generator is “shipped WITHOUT OIL in the engine”.
- No oil filter. None of the 26 portable manuals has an oil filter on the unit. A few Generac footnotes and a maintenance-kit sentence mention one anyway (see the disagreements below).
How to drain it
Three methods. 11 manuals have you tip the unit and pour the oil out through the filler (Honda EU2200i, EB2200i and EU3200i; Predator 59135; Generac iQ3500, GP3300i and GP2500i; WEN ×3; and the Firman W01682, which says to tilt the generator on its side). 11 have a drain plug or bolt (Honda EU3000is, Champion 100574-1, Predator 57480, both Westinghouse, Generac GP 3250 and GP5500E, both DuroMax, both A-iPower). 4 have a drain hose (Champion 100263 and 100264, Predator 59137, Firman P03617).
- Tools printed. A 10 mm wrench on the Westinghouse drain bolt (both manuals); a 12 mm socket and extension on the Champion 100574-1 drain bolt; a 12 mm hex wrench on both DuroMax drain plugs. The other manuals print no size.
- Washers. Westinghouse recommends a new crush washer (P/N 94007) at each change; the Honda EU3000is says to reinstall the drain plug with a new sealing washer.
- Drain pan. The Predator 57480 manual says to place a drain pan, “not included”, under the crankcase’s drain plug. Champion 100574-1 also notes the 12 mm socket is not included.
- Hoses. On Champion 100263 and 100264 you slide the spring clamp down the hose with pliers, pull the hose off its bracket and keep the hose end lower than the engine base; Firman P03617 also says the hose end must be lower than the engine base.
Where the manuals disagree with themselves
- Champion: 0.6 L or 0.6 qt? The 100263 and 100264 print “0.6 L (0.6 qt.)” in two places and “0.6 qt. (0.6 L)” in a third. 0.6 qt is 0.57 L, so the figures are not the same amount. The 100574-1 prints 20.3 fl. oz. (600 ml). The fill is “up to”, so fill to the level, not to a measured amount. The Generac iQ3500 and GP3300i print the same “0.6 L (0.6 qt.)”.
- Honda’s own conversions. The EU2200i and EB2200i print “14 oz (0.44 L)” and the EU3200i “15 oz (0.46 L)”. Converted, 14 US fl oz is 0.41 L and 0.44 L is 14.9 fl oz, a gap of about 6%; for the EU3200i the gap is 4%. The EU3000is (0.58 US qt, 0.55 L) agrees with itself.
- Westinghouse dipstick. Don’t screw it in (iGen4500) versus screw it fully in (iGen4500DF), above.
- Predator 57480 schedule. Its schedule ticks Change engine oil at “Monthly or every 20 hr. of use”, skips the 3-month/50-hour column, then ticks every later column. We can’t tell whether that means monthly, every 20 hours, or a longer interval (‡). Its grade guidance also differs between the spec table (p. 7), the text and the chart (p. 20).
- Generac footnotes. The GP5500E footnote says to change “oil and oil filter every month” under heavy load, and the maintenance-kit sentence in all four newer Generac manuals lists an oil filter, yet the units have none. The GP2500i has no oil row in its schedule table (its first change at 30 hours and 100-hour interval appear only in a footnote), and the GP3300i’s drain step says to “install oil drain plug” though no step removes one.
- What we did. We printed each manual as it reads and marked the conflict. Where a manual contradicts itself, ask the maker, using the contact details in the manual, before you rely on one reading.
Home standby generators (Generac air-cooled)
Generac’s home standby units are a different job from the portables above. We read three Generac air-cooled owner’s manuals; they don’t print the same oil advice, so the edition matters. Liquid-cooled units and other brands’ standby generators were not covered, and nor are Generac models outside these documents.
| Engine and output | Oil capacity including filter, as printed | Manual and page |
|---|---|---|
| 10 kW (G-Force 400, 460 cc) | Approx. 1.1 qt (1.03 L) | A0001846499 (2023), p. 9; A0000973303 (2022), PDF p. 15 |
| 14/18 kW (G-Force 800, 816 cc) | Approx. 2.2 qt (2.1 L) | A0001846499 (2023), p. 9; A0000973303 (2022), PDF p. 15 |
| 20–26 kW (G-Force 1000, 999 cc) | Approx. 1.9 qt (1.8 L) | A0001846499 (2023), p. 9 (the 2022 manual lists 20–24 kW, PDF p. 15) |
| 9 kW (GH-426, 426 cc) | Approx. 1.1 qt (1.03 L) | 0L6629 (2016), PDF p. 11 |
| 11 kW (GTH-530, 530 cc) | Approx. 1.7 qt (1.6 L) | 0L6629 (2016), PDF p. 11 |
| 16/20/22 kW (GT-999, 999 cc) | Approx. 1.9 qt (1.8 L) | 0L6629 (2016), PDF p. 11 |
Scroll the table sideways →
| Manual | Models listed | Oil | Filter number | Page |
|---|---|---|---|---|
| A0001846499 Rev C, 05/12/2023 | 10, 18, 24 kW (G0071710, G0072260/G0072280, G0072090, G0072100) | 5W-20 “GEO” after the 25-hour break-in; API SJ, SL or better; no temperature chart | 070185ES | p. 9, 11, 23–25 |
| A0000973303 Rev B, 02/25/2022 | 10–24 kW (G0072100, G0072090) | Same 5W-20 recommendation as Rev C, without the “GEO” name | 070185ES in the spec table (PDF p. 15), 070185E in the replacement-parts list (PDF p. 17) | PDF p. 15, 17 |
| 0L6629 Rev A, 07/12/16 | 9–22 kW (G0070430/G0070420, G0070360/G0070370) | “Required Oil—Synthetic SAE 5W-30 for all temperature ranges.” API SJ, SL or better | 070185E (replacement parts, PDF p. 13) | PDF p. 11, 13, 26–27 |
- Oil. After the 25-hour break-in the 2022 and 2023 manuals recommend Generac’s proprietary 5W-20 gaseous engine oil (GEO) for continuous use; the manual says Generac’s oil kits meet API SJ, SL or better and tells you not to use special additives; there is no temperature chart (p. 24). The older 0L6629 manual said “Required Oil—Synthetic SAE 5W-30 for all temperature ranges” (PDF p. 27). If your unit came with the older manual, that is the oil it names.
- First change. Change engine oil and filter after the first 25 hours (p. 23); the other two manuals say the same.
- Regular schedule. All three manuals print Schedule A (every two years or 200 hours) and Schedule B (every four years or 400 hours; 0L6629, PDF p. 26 too). We don’t reproduce the rule for choosing between them; read yours.
- Severe conditions. Change the oil and filter every year or 100 hours if the ambient temperature is below 40 °F (4.4 °C) or operation is continuous above 85 °F (29.4 °C) (p. 23).
- Filter. The spec table in the 2023 manual lists 070185ES; the 2022 manual lists 070185ES in the spec table and 070185E in the replacement-parts list; the 2016 manual lists 070185E. Use the number in your own manual.
- Dipstick and drain. Completely insert the dipstick into the dipstick tube and read the FULL mark (p. 24). Drain by pulling the drain hose free of its retaining clip and removing the cap.
- Fitting the filter. A light coat of oil on the filter gasket, hand-tight until the gasket contacts, then an additional three-quarter to one full turn (p. 25).
Oil and supplies
Some links below are Amazon affiliate links — as an Amazon Associate we may earn a small commission at no extra cost to you.
STP Premium Synthetic Blend 4-Cycle Small Engine Oil SAE 10W-30, 32 fl oz
A 32 fl oz bottle is more than the printed capacity of 23 of the 26 models in the table; the three that hold more are Predator 57480 (35.2 fl oz), DuroMax XP13000EH (40.5 fl oz), A-iPower AP10000ED (33.8 fl oz). It is a synthetic blend: the Honda and Predator manuals never mention synthetic oil, and the four newer Generac manuals, Champion 100263/100264 and the DuroMax XP13000EH say to wait until after break-in. Check your manual’s grade first (Generac and WEN call for SAE 30 or 30W in warm weather) and match the API service class on the label to the one it prints.
Briggs & Stratton 100074 5W-30 Synthetic Small Engine Oil, 32 oz bottle (count of 2)
A 5W-30 synthetic, sold as 32 oz bottles (listed with a count of 2). The manuals that allow it: the four newer Generac portables (whole range, after break-in), the Generac GP 3250 (below 10 °F), WEN (all temperature ranges), and Westinghouse, Champion, Firman, A-iPower and the DuroMax XP13000EH (synthetic 5W-30 on their charts, after break-in where the manual says so). Use it only if your own manual lists it.
Inverter generator oil funnel
15 of the 26 manuals say to fill through a funnel, and 17 ship one in the box. Honda, Predator and the Generac GP5500E and GP 3250 don’t; if yours didn’t, a funnel with a narrow spout helps you add oil slowly.
Generac 070185ES oil filter (home standby, air-cooled)
Part-number search for the filter in Generac’s 2022 and 2023 standby manuals. Match the part number in your own manual’s specifications: the older manual and one parts list print 070185E.
Frequently asked questions
What oil does a Honda EU2200i take, and how much?
SAE 10W-30 for general use, API SJ or later (or equivalent), according to the EU2200i manual (p. 51). The maximum oil capacity is printed as 14 oz (0.44 L); those two figures don’t convert to each other exactly (14 US fl oz is 0.41 L). First change after the first month or 20 hours, then every 6 months or 100 hours. The EU2200i has no oil filter; fill to the upper limit of the oil filler neck.
Can I use synthetic oil in my generator?
It depends on the manual. The four newer Generac portables say to use the supplied petroleum oil for break-in before synthetic; the older GP 3250 names synthetic 5W-30 only below 10 °F. Champion 100263 and 100264 allow it after 5 hours, DuroMax XP13000EH after 8 hours, and WEN says synthetic may be used. Westinghouse, Firman, A-iPower and Champion charts list a synthetic 5W-30. The Honda and Predator manuals never mention synthetic oil, so we can’t say what they allow.
How often should I change generator oil during an outage?
Follow the hours printed for your model: 100 hours on 18 manuals, 50 on 5, 25 on the WEN 56203i and about 20 on the DuroMax XP5500X. Nonstop, 100 hours is about 4.2 days and 50 hours about 2.1 days (hours ÷ 24). 9 manuals also say to change monthly under heavy load or in high temperatures.
Do I screw the dipstick in to check the oil?
15 manuals say no, 4 say screw it in (Westinghouse iGen4500DF, Generac GP5500E and both A-iPower), 4 say to fill to the edge or lip of the hole and 3 don’t say. The two Westinghouse manuals contradict each other, so follow the manual for your exact model.
Does my portable generator have an oil filter?
None of the 26 portable manuals we read has one on the unit. Generac’s air-cooled home standby generators do: the 2022 and 2023 manuals list filter 070185ES.
5W-30 or 10W-30 in winter?
Check your manual’s chart. Honda draws 5W-30 and 10W-30 as one band from about 5 °F; the Generac chart has 10W-30 down to -10 °F and synthetic 5W-30 over the whole range; WEN has 10W-30 for 0–40 °F; Westinghouse moves to 5W-30 below about 10 °F; the Predator 57480 table says 5W-30 at 32 °F or below. The Champion 100574-1 and DuroMax XP13000EH add that full synthetic 5W-30 aids starting below 41 °F.
Keep going
Bottom line: find your model’s row, then use the grade, capacity and interval it prints, and check the dipstick the way your manual says. 18 manuals say 10W-30 and 8 choose by temperature; none of the portables has an oil filter; and the hours add up fast in an outage. More specs on the small engines hub.
Sources
Owner’s manuals as PDFs on the makers’ own hosts, fetched 18 October 2026. Page numbers cited are printed pages.
- Honda EU2200i / EU2200i Companion: Owner's Manual 00X31-Z44-6010 (31Z44601), (c) 2018. cdn.powerequipment.honda.com; fetched 18 October 2026.
- Honda EB2200i: Owner's Manual 00X31-Z44-8000, (c) 2017. cdn.powerequipment.honda.com; fetched 18 October 2026.
- Honda EU3200i: Owner's Manual 31Z45600 / 00X31-Z45-6000, (c) 2022. cdn.powerequipment.honda.com; fetched 18 October 2026.
- Honda EU3000is (2009 printing): Owner's Manual 00X31-ZT7-6210 (31ZT7621), printing 2009.03. cdn.powerequipment.honda.com; fetched 18 October 2026.
- Champion 100263 (3100W inverter, YF170FD-L_G 192cc): Operator's Manual Model #100263, REV 20200923. www.championpowerequipment.com; fetched 18 October 2026.
- Champion 100264 (3200W dual fuel inverter, YF170FD-L_G 192cc): Operator's Manual Model #100264, REV 20210303. www.championpowerequipment.com; fetched 18 October 2026.
- Champion 100574-1 (3500W open frame inverter, YF172IV-L_G 224cc): Operator's Manual 100574-1, REV 20200520. www.championpowerequipment.com; fetched 18 October 2026.
- Predator (Harbor Freight) 59137 (3500 W inverter, 212 cc): Owner's Manual & Safety Instructions ITEM 59137 (no rev printed). manuals.harborfreight.com; fetched 18 October 2026.
- Predator (Harbor Freight) 59135 (2000 W inverter, 79.7 cc): Owner's Manual & Safety Instructions ITEM 59135. manuals.harborfreight.com; fetched 18 October 2026.
- Predator (Harbor Freight) 57480 (8750 W inverter, 420 cc): Owner's Manual & Safety Instructions ITEM 57480. manuals.harborfreight.com; fetched 18 October 2026.
- Westinghouse iGen4500 (224 cc): User Manual iGen4500 (no rev printed). cdn.westinghouseoutdoorpower.com; fetched 18 October 2026.
- Westinghouse iGen4500DF (dual fuel): User Manual iGen4500DF (no rev printed). cdn.westinghouseoutdoorpower.com; fetched 18 October 2026.
- Generac iQ3500 (212 cc): iQ3500 Portable Generator Owner's Manual, manual no. 007634. www.generac.com; fetched 18 October 2026.
- Generac GP3300i (149 cc): GP3300i Owner's Manual, manual no. 006087. www.generac.com; fetched 18 October 2026.
- Generac GP2500i (98 cc): GP2500i Owner's Manual, 011016. www.generac.com; fetched 18 October 2026.
- Generac GP5500E (GP Series manual): GP Series Portable Generator Owner's Manual, 020418. www.generac.com; fetched 18 October 2026.
- Generac GP 3250 (model 005982-0, older): Owner's Manual GP 3250, MODEL 005982-0 (doc 0H9247). productmanuals.generac.com; fetched 18 October 2026.
- WEN 56203i (2000W inverter, 79cc): 56203i Instruction Manual, 56203i.manual.20190426. cdn.shopify.com; fetched 18 October 2026.
- WEN 56360i (3600W inverter, 149cc): 56360i Instruction Manual, 56360i.manual.20240219. cdn.shopify.com; fetched 18 October 2026.
- WEN 56480iX (4800W inverter, 224cc): 56480iX Instruction Manual, 56480iX.manual.20231107. cdn.shopify.com; fetched 18 October 2026.
- Firman W01682 (inverter, 80 cc): Operator's Manual W01682, P/N 316745451 Rev:01. cdn.shopify.com; fetched 18 October 2026.
- Firman P03617 (208cc open frame): Owner's Manual P03617, P/N 336745464 Rev:04. cdn.shopify.com; fetched 18 October 2026.
- DuroMax XP13000EH (500 cc): XP13000EH User Manual, REV XP13000EH-02072025. cdn.shopify.com; fetched 18 October 2026.
- DuroMax XP5500X (224cc): XP5500X User Manual (no rev printed). cdn.shopify.com; fetched 18 October 2026.
- A-iPower SUA5001 (223cc): Portable Generator Owner's Manual SUA5001, REV00, P/N 32082-00000-00. cdn.shopify.com; fetched 18 October 2026.
- A-iPower AP10000ED (dual fuel, 420cc): Portable Generator Owner's Manual AP10000ED, REV00, P/N 32082-05377-00. cdn.shopify.com; fetched 18 October 2026.
- Honda EU2200i, later edition: 00X31-Z44-6020. cdn.powerequipment.honda.com; fetched 18 October 2026.
- Generac home standby: Owner's Manual, 60 Hz Air-Cooled Generators 10 kW to 26 kW, Part No. A0001846499 Rev. C 05/12/2023. productmanuals.generac.com; fetched 18 October 2026.
- Generac home standby: Owner's Manual, 60 Hz Air-Cooled Generators 10-24 kW, Part No. A0000973303 Rev. B 02/25/2022. productmanuals.generac.com; fetched 18 October 2026.
- Generac home standby: Owner's Manual, 60 Hz Air-Cooled Generators 9-22 kW, Part No. 0L6629 Rev. A 07/12/16. productmanuals.generac.com; fetched 18 October 2026.